  agilent E8663B analog signal generator data sheet the agilent E8663B is a fully synthesized signal generator with low phase noise and high output power. specifications apply over a 0 to 55 ? range, unless otherwise stated, and apply after a 45 minute warm-up time. supplemental characteristics, denoted as typical, nominal, or measured, provide additional (non-warranted) information at 25 ?, which may be useful in the application of the product. definitions specifications (spec): represents warranted performance for instruments with a current calibration. typical (typ): represents c haracteristic performance which is non-warranted. describes performance that will be met by a minimum of 80% of all products. nominal (nom): represents characteristic performance which is non-warranted. represents the value of a parameter that is most likely to occur; the expected mean or mode of all instruments. measured: represents characteristic performance which is non-warranted. represents the value of a parameter measured on an instrument during design verification.
2 specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 step (digital) sweep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 spectral purity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 frequency modulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 phase modulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 amplitude modulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 external modulation inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 internal modulation source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 pulse modulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 narrow pulse modulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 internal pulse generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 simultaneous modulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 remote programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 general specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 input/output descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 front panel connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 rear panel connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 options, accessories, and related products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 web resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 related agilent literature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 table of contents
3 range 1 option 503 100 khz to 3.2 ghz option 509 100 khz to 9 ghz resolution cw 0.001 hz all sweep modes 0.01 hz cw switching speed 2, 3 < 11 ms (typ) (7 ms (nom)) phase offset adjustable in nominal 0.1 increments frequency bands band frequency range n 4 1 100 khz to 250 mhz 1/8 2 > 250 to 500 mhz 1/16 3 > 500 mhz to 1 ghz 1/8 4 > 1 to 2 ghz 1/4 5 > 2 to 3.2 ghz 1/2 6 > 3.2 to 9 ghz 1 accuracy aging rate temperature effects line voltage effects (nom) internal timebase reference oscillator aging rate < 3 x10 ? /year or < ?.5 x 10 ?0 /day after 30 days temperature effects (typ) < ?.5 x 10 ? 0 to 55 ? line voltage effects (typ) < ? x 10 ?0 for ?0% change external reference frequency 10 mhz only lock range ?.0 ppm reference outpu t frequency 10 mhz amplitude > +4 dbm into 50 ? load (typ) external reference input amplitude 5 dbm ? db 5 input impedance 50 ? (nom) operating modes step sweep of frequency or amplitude or both (start to stop) ? list sweep of frequency or amplitude or both (arbitrary list) sweep rang e frequency sweep within instrument frequency range amplitude sweep within attenuator hold range (see ?utput?section) dwell time 1 ms to 60 s number of points 2 to 65535 (step sweep) 2 to 1601 per table (list sweep) triggering auto, external, single, or gpib settling time frequency < 8 ms (typ) 6 amplitude < 5 ms (typ) specifications frequency 1. performance is unspecified below 250 khz. 2. time from gpib trigger to frequency within 0.1 ppm of final frequency above 250 mhz or within 100 hz below 250 mhz. 3. add 19 ms (typical) when switching from greater than 3.2 ghz to less than 3.2 ghz (option 509 only). 4. n is a factor used to help define certain specifications within the document. 5. to optimize phase noise use 5 dbm 2 db. 6. 19 ms (typ) when stepping from greater than 3.2 ghz to less than 3.2 ghz (option 509 only). step (digital) sweep
4 power 1 (dbm) frequency range spec. (typ) option 503 and 509: 100 to 250 khz ?35 to +10 (nom) 250 khz to 3.2 ghz ?35 to +15 (+18) 250 khz to 3.2 ghz with option unw ?35 to +10 (+13) > 3.2 ghz to 9 ghz ?35 to +21 (+22) step attenuator 2 options 503 and 509 0 db and 5 db to 115 db in 10 db steps maximum available power (measured) attenuator hold range minimum from ?0 dbm to maximum specified output power with step attenuator in 0 db position. amplitude switching speed 3 alc on or off < 3 ms (typ) (without power search) output 1. maximum power specifications are warranted from 15 to 35 ?, and are typical from 0 to 15 ?. maximum power over the 35 to 55 ? range typically degrades less than 2 db. 2. the step attenuator provides coarse power attenuation to achieve low power levels. fine power l evel adjustment is provided by the alc (automatic level control) within the attenuator hold range. 3. to within 0.1 db of final amplitude within one attenuator range. add 10 to 50 ms when using power search. option 503 output power (measured) frequency (mhz) dbm 26 24 22 20 18 16 14 12 10 0.1 750 1700 2200 2700 3200
5 level accuracy 1 (db) frequency > +10 dbm +10 to 0 dbm 0 to ?0 dbm ?0 to ?0 dbm ?0 to ?0 dbm 100 to 250 khz ?.6 (nom) ?.6 (nom) ?.6 (nom) ?.7 (nom) ?.8 (nom) 250 khz to 2 ghz ?.6 ?.6 ?.6 ?.7 ?.8 > 2 to 9 ghz ?.8 ?.8 ?.8 ?.9 ?.0 level accuracy (measured) resolution 0.01 db temperature stability 0.01 db/? (typ) user flatness correction number of points 2 to 1601 points/table number of tables up to 10,000, memory limited path loss arbitrary, within attenuator range entry modes rem ote power meter 2 , remote bus, manual (user edit/view) output impedance 50 ? (nom) swr (internally leveled) 250 khz to 2 ghz < 1.4:1 (typ) > 2 ghz to 9 ghz < 1.6:1 (typ) leveling modes internal leveling, external detector leveling, millimeter source module, alc off external detector leveling range ?.2 mv to ?.5 v (nom) (?6 dbm to +4 dbm using agilent 33330d/e detector) bandwidth selectable 0.1 to 100 khz (nom) (note: not intended for pulsed operation) maximum reverse power 1/2 watt, 0 v dc option 503 level accuracy frequency (mhz) error (db) 0.2 0.15 0.1 0.05 0 ?.05 ?.1 ?.15 ?.2 0.1 200 800 1400 2000 2800 3200 1. specifications apply in cw and list/step sweep modes over the 15 to 35 ? temperature range, with attenuator hold off (normal operating mode). degradation outside this range, for alc power levels > ?0 dbm, is typically < 0.3 db. 2. compatible with agilent epm series (e4418b and e4419b) power meters.
6 harmonics 1 (dbc at +10 dbm or maximum specified output power, whichever is lower) < 10 mhz ?8 dbc (typical below 1 mhz) 10 mhz to 2 ghz ?0 dbc > 2 ghz to 9 ghz ?5 dbc harmonics (measured) sub-harmonics 2 (dbc at +10 dbm or maximum specified output power, whichever is lower) 100 khz to 9 ghz none non-harmonics (dbc at +10 dbm or maximum specified output power, whichever is lower, for offsets > 300 hz frequency spec typical 250 khz to 250 mhz ?5 ?2 for > 10 khz offsets > 250 mhz to 1 ghz ?0 ?8 > 1 to 2 ghz ?4 ?2 > 2 to 3.2 ghz ?8 ?6 > 3.2 to 9 ghz ?2 ?0 spectral purity 1. specifications are typical for harmonics beyond specified frequency range (beyond 50 ghz for option 567). 2. sub-harmonics are defined as carrier freq / n). 3. phase noise specifications are warranted from 15 to 35 ?. 4. measured at +10 dbm or maximum specified power, whichever is less. absolute ssb phase noise (dbc/hz) (cw) 3 offset from carrier frequency 1 hz 10 hz 100 hz 1 khz 10 khz 100 khz spec (typ) spec (typ) spec (typ) spec (typ) spec (typ) spec (typ) 250 khz to 250 mhz 4 ?8 (?6) 87 (?4) ?04 (?20) ?21 (?28) ?28 (?32) ?30 (?33) > 250 to 500 mhz 4 ?1 (?2) 88 (?8) ?08 (?18) ?26 (?32) ?32 (?36) ?36 (?41) > 500 mhz to 1 ghz 4 ?7 (?5) 84 (?3) ?01 (?11) ?21 (?30) ?30 (?34) ?30 (?35) > 1 to 2 ghz 4 ?1 (?8) 79 (?6) ?6 (?06) ?15 (?24) ?24 (?29) ?24 (?29) > 2 to 3.2 ghz ?6 (?4) 74 (?2) ?2 (?02) ?11 (?20) ?20 (?24) ?20 (?24) > 3.2 to 9 ghz ?7 (?4) 65 (?2) 81 (?2) ?01 (?09) ?10 (?14) ?10 (?15) residual ssb phase noise (dbc/hz) (cw) 3 offset from carrier frequency 1 hz 10 hz 100 hz 1 khz 10 khz 100 khz spec (typ) spec (typ) spec (typ) spec (typ) spec (typ) spec (typ) 250 khz to 250 mhz 4 (?4) ?00 (?07) ?10 (?18) ?20 (?26) ?28 (?32) ?30 (?33) > 250 to 500 mhz 4 (?01) ?05 (?12) ?15 (?22) ?24 (?31) ?32 (?36) ?36 (?41) > 500 mhz to 1 ghz 4 (?4) ?00 (?07) ?10 (?18) ?20 (?26) ?30 (?34) ?30 (?34) > 1 to 2 ghz 4 (?9) ?6 (?01) ?04 (?12) ?14 (?20) ?24 (?29) ?24 (?29) > 2 to 3.2 ghz (?5) ?2 (?7) ?00 (?08) ?10 (?16) ?20 (?24) ?20 (?24) > 3.2 to 9 ghz (?4) (?7) (?8) (?06) (?14) (?15)
7 measured phase noise with e5500 and plotted without spurs E8663B absolute ssb phase noise (measured) l(f) [dbc/hz] vs. f [hz] ?0 ?0 ?0 ?0 ?0 ?0 ?00 ?10 ?20 ?30 ?40 ?50 ?60 ?70 1 hz 10 hz 100 hz 1 khz 10 khz 100 khz 1 mhz 10 mhz 100 mhz 9 ghz 3.2 ghz 2 ghz 1 ghz 500 mhz E8663B am noise at 1 ghz (measured) l(f) [dbc/hz] vs. f [hz] ?0 ?0 ?0 ?0 ?0 ?0 ?00 ?10 ?20 ?30 ?40 ?50 ?60 ?70 1 hz 10 hz 100 hz 1 khz 10 khz 100 khz 1 mhz 10 mhz 100 mhz am noise E8663B residual phase noise (measured) l(f) [dbc/hz] vs. f [hz] ?0 ?0 ?0 ?0 ?0 ?0 ?00 ?10 ?20 ?30 ?40 ?50 ?60 ?70 1 hz 10 hz 100 hz 1 khz 10 khz 100 khz 1 mhz 10 mhz 100mhz 9 ghz 3 ghz 1 ghz residual phase noise standard phase noise
8 frequency modulation residual fm (rms, 50 hz to 15 khz bandwidth) cw mode < n x 4 hz (typ) broadband noise (cw mode at +10 dbm or maximum specified output power, whichever is lower, for offsets > 10 mhz) > 2.4 to 9 ghz < ?48 dbc/hz (typ) measured rms jitter 1 carrier sonet/sdh rms jitter unit intervals time frequency data rates bandwidth (?i) (fs) 155 mhz 155 mb/s 100 hz to 1.5 mhz 23 151 622 mhz 622 mb/s 1 khz to 5 mhz 19 30 2.488 ghz 2488 mb/s 5 khz to 20 mhz 56 22 maximum deviation 2 frequency maximum deviation 250 khz to 250 mhz 2 mhz > 250 to 500 mhz 1 mhz > 500 mhz to 1 ghz 2 mhz > 1 ghz to 2 ghz 4 mhz > 2 ghz to 3.2 ghz 8 mhz > 3.2 ghz to 9 ghz 16 mhz resolution 0.1% of deviation or 1 hz, whichever is greater deviation accuracy < 3.5% of fm deviation + 20 hz (1 khz rate, deviations < n x 800 khz) modulation frequency response (at 100 khz deviation) path [coupling] 1 db bandwidth 3 db bandwidth (typ) fm path 1 [dc] dc to 100 khz dc to 10 mhz fm path 2 [dc] dc to 100 khz dc to 1 mhz fm path 1 [ac] 20 hz to 100 khz 5 hz to 10 mhz fm path 2 [ac] 20 hz to 100 khz 5 hz to 1 mhz dc fm 3 carrier offset ?.1% of set deviation + (n x 8 hz) distortion < 1% (1 khz rate, deviations < n x 800 khz) sensitivity ? v peak for indicated deviation paths fm1 and fm2 are summed internally for composite modulation. either path may be switched to any one of the modulation sources: ext1, ext2, internal1, internal2. the fm2 path is limited to a maximum rate of 1 mhz. the fm2 path must be set to a deviation less than fm1. 1. calculated from phase noise performance in cw mode only at +10 dbm. for other frequencies, data rate, or bandwidths, please contact your sales representative. 2. through any combination of path1, path2, or path1 + path2. 3. at the calibrated deviation and carrier frequency, within 5 ? of ambient temperature at time of user calibration.
9 maximum deviation 1 frequency normal bw mode high bw mode 250 khz to 250 mhz 20 rad 2 rad > 250 to 500 mhz 10 rad 1 rad > 500 mhz to 1 ghz 20 rad 2 rad > 1 ghz to 2 ghz 40 rad 4 rad > 2 ghz to 3.2 ghz 80 rad 8 rad > 3.2 ghz to 9 ghz 160 rad 16 rad resolution 0.1% of set deviation deviation accuracy < ?% of deviation + 0.01 radians (1 khz rate, normal bw mode) modulation frequency response normal bw mode high bw mode rates (3 db bw) dc to 100 khz dc to 1 mhz (typ) 2 distortion < 1 % (1 khz rate, total harmonic distortion (thd), dev < n x 80 rad, normal bw mode) sensitivity ? v peak for indicated deviation paths f m1 and f m2 are summed internally for composite modulation. either path may be switched to any one of the modulation sources: ext1, ext2, internal1, internal2. the f m2 path must be set to a deviation less than f m1. depth linear mode exponential (log) mode (downward modulation only) maximum: alc on: > 90% > 20 db alc off with power search 4 or alc on with deep am 5 : > 95 % > 40 db settable: 0 to 100 % 0 to 40 db (0 to 100 %/volt sensitivity) (0 to 40 db/volt sensitivity) resolution: 0.1% 0.01 db accuracy (alc on, 1khz rate): < ?6% of setting + 1%) < (2% of setting +0.2db) ext sensitivity ? v peak for indicated depth ? v for indicated depth rates (3 db bandwidth, 30% depth) dc coupled 0 to 100 khz ac coupled 10 hz to 100 khz (useable to 1 mhz) distortion (1 khz rate, alc on, linear mode, total harmonic distortion) 30% am < 1.5% 60% am < 2% paths am1 and am2 are summed internally for composite modulation. either path may be switched to any one of the modulation sources: ext1, ext2, internal1, internal2. 1. through any combination of path1, path2, or path1 + path2. 2. path 1 is useable to 4 mhz for external inputs less than 0.3 v peak. 3. am specifications are typical. for carrier frequencies below 2 mhz, am is useable but not specified. unless otherwise stated, specifications apply with alc on and envelope peaks within alc operating range (?0 dbm to maximum specified power, excluding step-attenuator setting). 4. alc off is used for narrow pulse modulation and/or high am depths, with envelope peaks below alc operating range. carrier power level will be accurate after a power search is executed. 5. alc on with deep am provides high am depths together with closed-loop internal leveling. this mode can be used with a repetitive am waveform (frequency > 10 hz) with peaks > ? dbm (nominal, excluding step-attenuator setting). phase modulation amplitude modulation 3 (typical)
10 modulation types am, fm, and f m input impedance 50 or 600 ? (nom) switched high/low indicator (100 hz to 10 mhz bw, activated when input level error exceeds 3% (nom) ac coupled inputs only) dual function generators provide two independent signals (internal1 and internal2) for use with am, fm, f m, or lf out. waveforms sine, square, positive ramp, negative ramp, triangle, gaussian noise, uniform noise, swept sine, dual sine 1 rate range sine 0.5 hz to 1 mhz square, ramp, triangle 0.5 hz to 100 khz resolution 0.5 hz accuracy same as timebase lf out output internal1 or internal2. also provides monitoring of internal1or internal2 when used for am, fm, or f m. amplitude 0 to 3 v peak , (nom) into 50 ? output impedance 50 ? (nom) swept sine mode: (frequency, phase continuous) operating modes triggered or continuous sweeps frequency range 1 hz to 1 mhz sweep rate 0.5 hz to 100 khz sweeps/s, equivalent to sweep times 10 us to 2 s resolution 0.5 hz (0.5 sweep/s) external modulation inputs (ext1 & ext2) internal modulation source 1. internal2 is not available when using swept sine or dual sine modes.
11 pulse modulation 1, 2 1. with alc off, specs apply after the execution of power search. specifications apply with atten hold off (default mode for instruments with attenuator), or alc level bet ween ? and +10 dbm or maximum specific power, whichever is lower. above 50 ghz, pulse modulation is useable; however performance is not warranted. 2. power search is a calibration routine that improves level accuracy with alc off. the instrument microprocessor momentarily closes the alc loop to find the modulator drive setting necessary to make the quiescent rf level equal to an entered value, then opens the alc loop while maintaining that modulator drive setting. when executing power search, rf power will be present for typically 10 to 50 ms; the step attenuator can be set to automatically switch to maximum attenuation to protect sensitive devices. power search can be configured to operate either automatically or manually at the carrier frequency, or over a user-definable frequency range. 3. with attenuator in 0 db position. video feed-through decreases with attenuator setting. 500 mhz to 3.2 ghz above 3.2 ghz on/off ratio 80 db (typ) 80 db rise/fall times (tr, tf) 100 ns (typ) 6 ns (typ) minimum pulse width internally leveled 2 us 1 us level hold (alc off with power search) 0.5 us 0.15 us repetition frequency internally leveled 10 hz to 250 khz 10 hz to 500 khz level hold (alc off with power search) dc to 1 mhz dc to 3 mhz level accuracy (relative to cw) internally leveled ?.5 db ?.5 db level hold (alc off with power search) 0.5 db (typ) ?.5 db (typ) width compression ?0 ns (typ) ? ns (typ) (rf width relative to video out) video feed-through 3 < 200 mv (typ) < 2 mv (typ) video delay (ext input to video) 50 ns (nom) 50 ns (nom) rf delay (video to rf output) 270 ns (nom) 35 ns (nom) pulse overshoot < 10% (typ) < 10% (typ) input level +1 v peak = rf on +1 v peak = rf on input impedance 50 ? (nom) 50 ? (nom) 10 mhz to 3.2 ghz above 3.2 ghz on/off ratio 80 db 80 db rise/fall times (tr, tf) 10 ns (8 ns typical) 10 ns (6 ns typical) minimum pulse width internally leveled 1 us 1 us level hold (alc off with power search) 20 ns 20 ns repetition frequency internally leveled 10 hz to 500 khz 10 hz to 500 khz level hold (alc off with power search) dc to 5 mhz dc to 10 mhz level accuracy (relative to cw) internally leveled ?.5 db ?.5 db (0.15 db typical) level hold (alc off with power search) 1.3 db (typ) ?.5 db (typ) narrow pulse modulation 1, 2 (option unw)
12 10 mhz to 3.2 ghz above 3.2 ghz width compression ? ns (typ) ? ns (typ) (rf width relative to video out) video feed-through 1 < 125 mv (typ) < 2 mv (typ) video delay (ext input to video) 50 ns (nom) 50 ns (nom) rf delay (video to rf output) 45 ns (nom) 35 ns (nom) pulse overshoot < 15% (typ) < 10% (typ) input level +1 v peak = rf on +1 v peak = rf on input impedance 50 ? (nom) 50 ? (nom) modes free-run, triggered, triggered with delay, doublet, and gated. triggered with delay, doublet, and gated require external trigger source. period (pri) (tp) 70 ns to 42 s (repetition frequency: 0.024 hz to 14.28 mhz) pulse width (tw) 10 ns to 42 s delay (td) free-run mode 0 to ?2 s triggered with delay and doublet modes 75 ns to 42s with ?0 ns jitter resolution 10 ns (width, delay, and pri) measured pulse modulation envelope freq = 10ghz, amp = 10dbm, alc = off, pulse width = 50ns timebase (nsec) 0 10 20 30 40 50 60 70 80 90 100 sync output video output rf pulse output t d t m t w t rf v f t f t r v or t p 50% 50% 10% 90% 50% internal pulse generator (with or without option unw) 1. with attenuator in 0 db position. video feed-through decreases with attenuator setting. td video delay (variable) tw video pulse width (variable) tp pulse period (variable) tm rf delay trf rf pulse width tf rf pulse fall time tr rf pulse rise time vor pulse overshoot vf video feedthrough
13 all modulation types (fm, am, f m, and pulse modulations) may be simultaneously enabled except: fm with f m, and linear am with exponential am. am, fm, and f m can sum simultaneous inputs from any two sources (ext1, ext2, internal1, or internal2). any given source (ext1, ext2, internal1, or internal2) may be routed to only one activated modulation type. interfaces gpib (ieee-488.2,1987) with listen and talk, rs-232, and 10baset lan interface. control languages scpi version 1997.0. the E8663B will emulate the applicable commands for the agilent 8662a/63a signal generators, pr oviding general compatibility with ate systems and the agilent e5500 phase noise test system. ieee-488 functions sh1, ah1, t6, te0, l4, le0, sr1, rl1, pp0, dc1, dt0, c0, e2. iso compliant this family of signal generators is manufactured in an iso-9001 registered facility in concurrence with agilent commitment to quality. agilent io libraries agilents io library suite ships with the E8663B to help you quickly establish an error-free connection between your pc and instruments ? regardless of the vendor. it provides robust instrument control and works with the software development environment you choose. remote programming simultaneous modulation
14 1. storage below ?0 ? instrument states may be lost. 2. as is the case with all signal generation equipment, phase noise specifications are not warranted in a vibrating environment. power requirements 100 to 120 vac, 50 to 60 hz 220 to 240 vac, 50 to 60 hz < 250 w typical, 650 w maximum operating temperature range 0 to 55 ? storage temperature range 1 ?0 to 70 ? altitude < 4,572 m (15,000 ft.) environmental testing samples of this product have been tested in accordance with the agilent environmental test manual and verified to be robust against the environmental stresses of storage, transporta- tion, and end-use; those stresses include but are not limited to temperature, humidity, shock, vibration, altitude, and power line conditions. test methods are aligned with iec 60068-2 and levels are similar to mil-prf-28800f class 3. 2 emc meets the conducted and radiated interference and immunity requirements of iec/en 61326-1. meets radiated emission requirements of cispr pub 11/1997 group 1 class a. storage registers memory is shared by instrument states and sweep list files. there is 14 mb of flash memory available in the E8663B. depending on how the memory is used, a maximum of 1000 instrument states can be saved. security display blanking memory clearing functions (see application note security of agilent signal generators issues and solutions , literature number 5989-1091en) compatibility agilent epm series power meters. self-test internal diagnostic routine tests most modules (including microcircuits) in a preset condition. for each module, if its node voltages are within acceptable limits, then the module ?asses? the test. weight < 22 kg (48 lb.) net, < 30 kg (68 lb.) shipping dimensions 178 mm h x 426 mm w x 515 mm d (7?h x 16.8?w x 20.3?d in.) recommended calibration cycle 24 months general specifications
15 rf output output impedance 50 ? (nom) option 503 and 509 type-n alc input used for negative external detector leveling. nominal input impedance 120 k ? , damage level ?5 v. lf output outputs the internally generated lf source. nominal output impedance 50 ? . external input 1 drives either am, fm, or f m. nominal input impedance 50 or 600 ? , damage levels are 5 v rms and 10 v peak . external input 2 drives either am, fm, or f m. nominal input impedance 50 or 600 ? , damage levels are 5 v rms and 10 v peak . pulse/trigger gate input accepts input signal for external fast pulse modulation. also accepts external trigger pulse input for internal pulse modulation. nominal impedance 50 ? . damage levels are 5 v rms and 10 v peak . pulse video out outputs a signal that follows the rf output in all pulse modes. ttl-level compatible, nominal source impedance 50 ? . pulse sync out outputs a synchronizing pulse, nominally 50 ns width, during internal and triggered pulse modulation. ttl-level compatible, nominal source impedance 50 ? . auxiliary interface (dual mode) used for rs-232 serial communication and for master/slave source synchronization. (9-pin subminiature female connector). gpib allows communication with compatible devices lan allows 10baset lan communication 10 mhz input accepts an external reference (timebase) input (at 10 mhz) nominal input impedance 50 ? damage levels > +10 dbm 10 mhz output outputs internal or external reference signal. nominal output impedance 50 ? . nominal output power +8 dbm. 1 ghz output provides a 1 ghz low noise frequency reference output. sweep output (dual mode) supplies a voltage proportional to the rf power or frequency sweep ranging form 0 volts at the start of sweep to +10 volts (nom) at the end of sweep, regardless of sweep width. during cw operation, supplies a voltage proportional to the output frequency, +10 volts (nom) corresponding to the maximum specified frequency. output impedance: < 1 ? (nom), can drive 2000 ? . input/output descriptions front panel connectors (all connectors are bnc female unless otherwise noted.) 1 rear panel connectors (all connectors are bnc female unless otherwise noted.) 1 1. digital inputs and output are 3.3 v cmos unless indicated otherwise. inputs will accept 5 v cmos, 3 v cmos, or ttl voltage le vels.
16 stop sweep in/out open-collector, ttl-compatible input/output. in sweep operation, provides low level (nominally 0 v) during sweep retrace and bandcross intervals, and high level during the forward portion of the sweep. sweep will stop when grounded externally, sweep will resume when allowed to go high. trigger output (dual mode) outputs a ttl signal. high at start of dwell, or when waiting for point trigger; low when dwell is over or point trigger is rece ived. when using lf out, provides 2 us pulse at start of lf sweep. trigger input accepts ttl signal for triggering point-to-point in manual sweep mode, or to trigger start of lf sweep. damage levels +10 v or ? v. source module interface non-functional. source settled provides an output trigger that indicates when the signal generator has settled to a new frequency or power level. high indicates source not settled, low indicates source settled. z-axis blank/markers supplies ? v (nom) level when the rf frequency is at a marker frequency. 10 mhz efc accepts an external dc voltage, ranging from ? v to +5 v, for electronic frequency control (efc) of the internal 10 mhz reference oscillator. this voltage inversely tunes the oscillator about its center frequency approximately ?.07 ppm/v. the nominal input impedance is greater than 1 m ? . 1 ghz out low noise 1 ghz reference output signal, approximately +5 dbm (nom).
17 model/option description E8663B-503 frequency range from 100 khz to 3.2 ghz E8663B-509 frequency range from 100 khz to 9 ghz E8663B-unw narrow pulse modulation E8663B-1em moves all front panel connectors to the rear panel E8663B-1cn front handle kit E8663B-1cm rackmount flange kit E8663B-1cp rackmount flange and front handle kit E8663B-uk6 commercial calibration certificate and test data E8663B-cd1 cd-rom containing the english documentation set E8663B-aba printed copy of the english documentation set E8663B-0bw printed copy of the assembly-level service guide 8120-8806 master/slave interface cable 9211-2656 transit case 9211-7481 transit case with wheels options, accessories, and related products
18 for more information about renting, leasing or financing agilents latest technology, visit: www.agilent.com/find/buy/alternatives for more accessory information, visit: www.agilent.com/find/accessories for additional description of agilents io libraries suite features and installation requirements, please go to: www.agilent.com/find/iosuite/database security of agilent signal generators issues and solutions, literature number 5989-1091en web resources related agilent literature
19
www.agilent.com/find/emailupdates get the latest information on the products and applications you select. www.agilent.com/find/agilentdirect quickly choose and use your test equipment solutions with confidence. www.agilent.com/find/open agilent open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. agilent offers open connectivity for a broad range of system-ready instruments, open industry software, pc-standard i/o and global support, which are combined to more easily integrate test system development. agilent email updates agilent direct agilent open www.agilent.com for more information on agilent technologies products, applications or services, please contact your local agilent office. the complete list is available at: www.agilent.com/find/contactus north america canada (877) 894-4414 latin america 305 269 7500 united states (800) 829-4444 asia pacific australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 112 929 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 thailand 1 800 226 008 europe austria 0820 87 44 11 belgium 32 (0) 2 404 93 40 denmark 45 70 13 15 15 finland 358 (0) 10 855 2100 france 0825 010 700* *0.125 fixed network rate germany 01805 24 6333** **0.14 /minute ireland 1890 924 204 israel 972-3-9288-504/544 italy 39 02 92 60 8484 netherlands 31 (0) 20 547 2111 spain 34 (91) 631 3300 sweden 0200-88 22 55 switzerland (french) 41 (21) 8113811(opt 2) switzerland (german) 0800 80 53 53 (opt 1) united kingdom 44 (0) 118 9276201 other european countries: www.agilent.com/find/contactus revised: october 24, 2007 product specifications and descriptions in this document subject to change without notice. ?agilent technologies, inc. 2004-2007 printed in usa, november 20, 2007 5989-4866en remove all doubt our repair and calibration services will get your equipment back to you, performing like new, when promised. you will get full value out of your agilent equipment throughout its lifetime. your equipment will be serviced by agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. you will always have the utmost confidence in your measurements. agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. for more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt


▲Up To Search▲   

 
Price & Availability of E8663B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X